KC-18 G18 Vacuum Relay specifications
|
Item |
Unit |
Value |
|
Voltage (Peak), Test Max., Contacts & to Base (15 µA Leakage
Max., dc or 60Hz) ★ |
kV |
17 |
|
Voltage (Peak), Operating Max. Contacts & to Base (15 µA
Leakage Max.) |
|
|
|
dc or 60 Hz ★ |
kV |
15 |
|
2.5 MHz ★ |
kV |
12 |
|
16 MHz ★ |
kV |
9 |
|
32 MHz ★ |
kV |
7 |
|
Current, Continuous Carry Max (RMS) |
|
|
|
dc or 60 Hz ★ |
Amps |
50 |
|
2.5 MHz ★ |
Amps |
30 |
|
16 MHz ★ |
Amps |
17.5 |
|
32 MHz ★ |
Amps |
10 |
|
Resistance, Contact Max 1A, 28 Vdc ★ |
Ω |
0.012 |
|
Rated Coil Voltage ★ |
Vdc |
12
13.5
24
26.5
115 |
|
DC Coil Resistance |
±10% |
72.5
83
180
270
3000 |
|
Coil Hi-Pot (V RMS, 60 Hz) |
V |
500 |
|
Capacitance |
|
|
|
Across Open Contacts |
pF |
0.5 |
|
Contacts to Ground |
pF |
1 |
|
Operate Time |
ms |
15 |
|
Release Time |
ms |
9 |
|
Bounce MAX |
ms |
3 |
|
Pull-in Voltage 25℃ 26.5 Vdc Coil |
V |
9
10
15
16
70 |
|
Dropout Voltage -55 to 125 ℃ 26.5 Vdc Coil |
V |
0.8-4
0.8-4.5
1.4-6.5
1.5-7
3-30 |
|
Mechanical life ★ |
Operation |
1 million |
|
Vibration, Operating, Sine (55-500 Hz Peak) |
G's |
10 |
|
Shock, Operating, 1/2 Sine11ms (Peak) |
G's |
50 |
|
Maximum Weight |
g |
86 |