KC-2
KC-11 Vacuum Relay specifications
|
Item |
Unit |
Value |
| Voltage (Peak), Test Max.,
Contacts & to Base (15 µA Leakage Max., dc or 60Hz) ★
|
kV |
17 |
| Voltage (Peak), Operating
Max. Contacts & to Base (15 µA Leakage Max.) |
|
|
| dc or 60 Hz ★
|
kV |
15 |
| 2.5 MHz ★ |
kV |
12 |
| 16 MHz ★ |
kV |
9 |
| 32 MHz ★ |
kV |
7 |
| Current, Continuous Carry Max
(RMS) |
|
|
| dc or 60 Hz ★
|
Amps |
50 |
| 2.5 MHz ★ |
Amps |
30 |
| 16 MHz ★ |
Amps |
17.5 |
| 32 MHz ★ |
Amps |
10 |
| Resistance, Contact Max 1A,
28 Vdc ★ |
Ω |
0.012 |
| Rated Coil Voltage ★
|
Vdc |
12
13.5
24
26.5
115 |
| DC Coil Resistance |
±10% |
72.5
83
180
270
3000 |
| Coil Hi-Pot (V RMS, 60 Hz) |
V |
500 |
| Capacitance |
|
|
| Across Open Contacts |
pF |
0.5 |
| Contacts to Ground |
pF |
1 |
| Operate Time |
ms |
15 |
| Release Time |
ms |
9 |
| Bounce MAX |
ms |
3 |
| Pull-in Voltage 25℃ 26.5 Vdc
Coil |
V |
9
10
15
16
70 |
| Dropout Voltage -55 to 125℃
26.5 Vdc Coil |
V |
0.8-4
0.8-4.5
1.4-6.5
1.5-7
3-30 |
| Mechanical life ★
|
Operation |
1 million |
| Vibration, Operating, Sine
(55-500 Hz Peak) |
G's |
10 |
| Shock, Operating, 1/2
Sine11ms (Peak) |
G's |
50 |
| Maximum Weight |
g |
86 |

GREENSTONE USA
Copyright © 2001 GREENSTONE USA All rights reserved.
Revised: