Call us Toll Fee
at: 877-206-5021 
CW Magnetron's list:
Part Number
|
Output
|
Frequency
|
CK-611
|
30KW
|
915 MHZ
|
CK-619
|
10KW
|
2450MHZ
|
CK-147
|
5KW
|
915MHZ
|
75KW
CL band CW Magnetron
Specification for the 75KW CL band CW Magnetron:
The CW75 is a 75KW CL band magnetron with a
fixed-frequency non-integral-magnet
metal-ceramic structure directly-heated by a pure tungsten cathode,
high power continuous-wave magnetron with a wavelength of 33cm. The
anode is water cooled and cathode by air. The tube connected
directly with waveguide BJ-9 mainly is used in wave heating as power
source.
Main performance:
Frequency 915MHz±10MHz
Pout
≥75kW(V.S.W.R≤1.1)
Anode voltage 17kV~18kV
Anode current 5.0A
Filament voltage 12.6V±0.5V
Filament current 115A
Warm-up time ≥180s
Magnetic field 0.12T
Operating conditions:
Anode cooling water flow rate ≥0.018m3/min
(final temp.≤
50℃)
Anode cooling water resistance
≥4Kω/cm3
Out –leading cooling air flow rate ≥12m3/min
Output window cooling air flow rate ≥0.7 m3/min
Ambient temperature room temperature
L.V.S.W.R: <1.5
Warm-up filament current 115A
Filament heating time ≥180s
Operating filament current 85A
Anode voltage 17.5kV
Anode current 5.0A
Limit parameters:
Min. Max. Unit
Filament surge current
250 A
Filament heating current
116 A
Filament heating time
60 s
Anode voltage
18.5 kV
Anode current
2 6 A
L.V.S.W.R
1.5
Anode cooling water flow rate
10
m3/min
Anode cooling water final temperature
50
℃
Metal surface
temp.
130 ℃
Ceramic surface
temp.
150 ℃
Typical operating conditions:
Heating filament current 115A
Operating filament current 85A
Anode voltage 17.5kV
Anode current
5.0A
Pout
75kW
Frequency range
915MHz
Magnetic flux density 0.12T
Tubes not used for a long period of time or new tubes should be
refined before operation, heat the filament, adjust If=115A,
add the high-voltage after 15 minutes:
Ua Ia If
t
11kV 2A 110A 15minutes
12.5kV 2.5A 105A 15 minutes
13kV 3A 100A 15 minutes
14.5kV 3.5A 98A 15 minutes
15.5kV 4A 95A 30 minutes
16.5kV 4.5A 88A 30 minutes
17.2kV 5A 82A 60 minutes
The min. anode current of the magnetron is 2A while its operating.
Outline
and dimension:
|
Code |
Min. |
Nominal |
Max. |
|
A
B
C
D |
108.5
φ91
φ124
— |
110
φ92
—
— |
112.5
φ93
φ125
465 |
|
E
F
G |
φ76
φ35.2
φ56.8 |
φ76.2
φ35.4
φ57 |
φ76.4
φ35.6
φ57.2 |
|
H
I
J
L
M
N
O
P
Q
R |
—
—
—
105
—
—
—
—
—
— |
φ8
—
—
110
φ76
—
1/2’-20
6ŚM6
15°
90° |
—
150
φ101.3
115
—
230
—
—
—
— |

Dimensions
are in mm.
GREENSTONE USA
Copyright © 2001 GREENSTONE USA All rights reserved.
Revised:
July 05, 2012
|