Call us Toll Fee
at: 877-206-5021 
MEDIUM VOLTAGE VACUUM CONTACTORS & STARTERS
Greenstone USA vacuum contactors and starters are used in many different applications such as: Mining, petroleum, control
electric loads such as electric motors.
Our vacuum contactors are supplied with our state of the art vacuum interrupters that allow the moving contact to be closed and pulled open from the outside without leaking air into the bottle, this is very critical when you are using vacuum contactors in flammable areas.
Below is a list of vacuum contactors we manufacture, if you do not find the vacuum contactor you are looking for on the please contact us with your vacuum contactor requirements and we custom build one to fit your application.
Medium Voltage Vacuum Contactors
& Starter Ratings 1.5KV, 2.5KV, 3.6KV, 5.0KV & 7.2KV
|
Description |
200A |
400A |
600A |
1200A |
|
Catalog
Number & Rated Voltage |
2.5KV |
VC88/3/200/2500 |
VC88/3/400/2500 |
VC88/3/600/2500 |
VC88/3/1200/2500 |
|
5.0KV |
VC88/3/200/5000 |
VC88/3/400/5000 |
VC88/3/600/5000 |
VC88/3/1200/5000 |
|
7.2KV |
VC88/3/200/7200 |
VC88/3/400/7200 |
VC88/3/600/7200 |
VC88/3/120 |
|
Vacuum Contactor power ratings |
|
Operational rated current |
200A |
400A |
600A |
800A/1200A |
|
Operational rated frequency |
50/60Hz |
50/60Hz |
50/60Hz |
50/60Hz |
|
E1
interrupt rating |
2.5 KV |
20 MVA
Equivalent to 4.62 KA |
------- |
|
MVA & KA
value |
5.0 KV |
40 MVA
Equivalent to 4.62 KA |
------- |
|
Contactor only |
7.2 KV |
60 MVA
Equivalent to 4.81 KA |
------- |
|
E2 fuse
rating |
400 MVA
45.7 KA RMS |
------- |
|
MVA & KA |
5.0 KV |
38 R
max. fuse size |
|
Withstand KA |
5.0 KV |
57.8 KA
-Peak,38
R -Fuse |
------- |
|
Short
time current |
1Sec. KA |
6 |
7 |
9 |
12 |
|
5Sec. KA |
4 |
5 |
6 |
9 |
|
15Sec
.KA |
2 |
2.6 |
3 |
6 |
|
Switching frequency |
300/Hr |
|
Elec.
life at rated current |
.6×106 |
.40×106 |
.250×106 |
.250×106 |
|
Mechanical life |
.75×106 |
|
Dielectric strength |
20KV
1min |
|
Impulse
withstand B.I.L |
1.2×50us |
|
60KV |
|
Chopping
current max. |
.9A |
|
Vacuum Contactor control ratings AC & DC |
|
Rated
control voltage |
120/240V
50/60Hz AC |
125/250VDC |
|
Allowable fluctuation |
+10-15% |
+10-20% |
|
Closing
power VA/Duration |
650
VA/45 MS |
1300
VA/45 MS |
|
Holding
power |
7 VA AC
.47A DC |
14 VA AC
.924A DC |
|
Opening
time Ave. |
90 MS at
60Hz |
|
Closing
time Ave. |
40 MS at
60Hz |
|
Pick up
voltage |
Min. |
102 V or
less |
|
Drop out
voltage |
Ave. |
70% or
less |
|
Recommended control trans. |
(AC
Only) |
300 VA |
|
600VA |
|
Vacuum contactor application
conditions |
|
Standard
auxiliary contact ratings |
Current |
Continuous AC/DC 10A/5A |
|
Voltage |
600V
Max.-48V Min. NEMA A600 (AC) P600 (DC) |
|
AC |
Make/Break 7200VA/720 VA |
|
DC |
Make/Break 125/250 V 138VA 300/600V 138VA |
|
Additional auxiliary contact relay ratings |
Current |
Continuous AC/DC 10A/2.5A |
|
Voltage |
600V
Max.-48V Min. NEMA A600 (AC) Q300 (DC) |
|
AC |
Make/Break 7200VA/720VA |
|
DC |
Make/Break 125/250V/69VA |
|
Weight |
|
48 lbs. |
96 lbs. |
|
|
|
|
|
|
|
|
Voltage KV |
|
2.5 |
3.3 |
4.16 |
6.6 |
|
Motor Type |
Current |
Motor HP |
|
.8
P.F.Ind. or syn motor |
200A |
900 |
1250 |
1500 |
2500 |
|
1.0
P.F.syn motor |
200A |
1000 |
1500 |
1750 |
2750 |
|
.8
P.F.Ind. or syn Motor |
400A |
1750 |
2250 |
3000 |
5000 |
|
1.0
P.F.syn motor |
400A |
2000 |
2500 |
3500 |
2520 |
|
.8
P.F.Ind. or syn motor |
600A |
2250 |
3250 |
4500 |
6750 |
|
1.0
P.F.syn motor |
600A |
2250 |
3500 |
4750 |
7000 |
|
.8
P.F.Ind. or syn Motor |
800A |
2750 |
4000 |
5500 |
8000 |
|
Transformer Load KVA |
|
Three
phase transformer |
200A |
750 |
1000 |
1500 |
2000 |
|
400A |
1500 |
2000 |
3000 |
4000 |
|
600A |
2500 |
3000 |
4250 |
6000 |
|
800A |
2750 |
3750 |
5250 |
7500 |
|
1200A |
4100 |
5000 |
7000 |
10000 |
|
Capacitor Load KVAR |
|
Three
phase capacitor |
200A |
550 |
750 |
1050 |
1500 |
|
400A |
1125 |
1500 |
2250 |
3000 |
|
600A |
1650 |
2250 |
3375 |
4500 |
|
800A |
2200 |
2900 |
4500 |
5000 |
|
1200A |
2750 |
3750 |
5625 |
7500 |
|
Vacuum Contactor current rating |
Maximum Horsepower Ratings |
Open Type |
|
(A) |
.8pf Ind. Or Syn. Motor |
1.0pf Syn. Motor |
Catalog No. |
|
2500Volts |
|
|
|
|
200 |
900 |
1000 |
VC88/3/200/2500 |
|
400 |
1750 |
2000 |
VC88/3/400/2500 |
|
600 |
2250 |
2500 |
VC88/3/600/2500 |
|
800 |
2750 |
----- |
VC88/3/800/2500 |
|
1200 |
----- |
----- |
VC88/3/1200/2500 |
|
4160Volts |
|
|
|
|
200 |
1500 |
1750 |
VC88/3/200/5000 |
|
400 |
3000 |
3500 |
VC88/3/400/5000 |
|
600 |
4500 |
4750 |
VC88/3/600/5000 |
|
800 |
5500 |
----- |
VC88/3/800/5000 |
|
1200 |
----- |
----- |
VC88/3/1200/5000 |
|
6600Volts |
|
|
|
|
200 |
2500 |
2750 |
VC88/3/200/7200 |
|
400 |
5000 |
5250 |
VC88/3/400/7200 |
|
600 |
6750 |
7000 |
VC88/3/600/7200 |
|
800 |
8000 |
----- |
VC88/3/800/7200 |
|
1200 |
----- |
----- |
VC88/3/1200/7200 |
|
Coil Table |
|
Voltage
AC |
Suffix |
Voltage
DC |
Suffix |
|
120 |
-76 |
125 |
-125 |
|
240 |
-26 |
250 |
-250 |


|
80/60V |
160A |
320A |
600A |
1000A |
|
3 Pole |
1.5KV |
VC88/3/160/1500 |
VC88/3/320/1500 |
VC88/3/600/1500 |
VC88/3/1000/1500 |
|
3.6KV |
VC88/3/160/3600 |
VC88/3/320/3600 |
VC88/3/600/3600 |
VC88/3/1000/3600 |
|
Vacuum Contactor Power Ratings |
|
|
Rated Insulating And Operational Voltage |
1500/3600 |
|
|
Rated Operational Current |
160 |
320 |
600 |
1000 |
|
|
Rated Frequency |
50/400Hz |
|
|
Making Current |
1600 |
3200 |
6000 |
6000 |
|
|
Breaking Current |
1600 |
3200 |
6000 |
6000 |
|
|
Dielectric Strength/BIL |
6KV-1 min. /45KV. 1.2×50 Micro/Sec. |
|
|
Interrupting Current |
4400 |
5000 |
6000 |
6000 |
|
|
Withstand Current |
30KA-3Hz |
|
|
Short Time Current |
1Sec. |
5000 |
7000 |
9000 |
11000 |
|
|
2Sec. |
3000 |
5000 |
7000 |
9000 |
|
|
Mechanical Life |
2×106 |
|
|
Electrical Life At Rated Current – AC3 Duty |
1×106 |
|
|
Switching Frequency |
1200/hr |
|
|
Chop Current |
Min. |
.55A |
|
|
Max. |
.9A |
|
|
Vacuum Contactor Control Ratings |
|
|
Description |
160/320A |
600A |
1000A |
|
|
Rated Control Voltage |
120/240V 50/400Hz |
|
|
Allowable Fluctuation |
+10% of rated -25%voltage |
|
Closing Power VA/Duration |
950VA/17MS |
1900VA/17MS |
2850VA/17MS |
|
Holding Power |
9VA |
18VA |
27VA |
|
Opening Time Ave. |
90MS at 60Hz |
|
Closing Time Ave. |
17MS at 60Hz |
|
Picking Up Voltage |
90V |
|
Drop Out Voltage |
70℅or less |
|
Recommended Control Transformer |
When Required 250VA |
When Required 500VA |
When Required 750VA |
|
Vacuum Contactor Application
Conditions |
|
Installation |
All planes up to 6600 ft.(2000m) |
|
Ambient |
Storage |
-65℉(-54℃)+160℉(71℃) |
|
Operating |
-40℉(-40℃)+135℉(67℃) |
|
Vibration/Shock |
40Hz-2G/30G |
|
Weight 160/320A |
12lbs.(5.45kg) |
24lbs.(11kg) |
36lbs,(16.36kg) |
|
Dimensions (mm) |
225×189×200 |
450×189×200 |
676×189×200 |
| |
|
|
|
|
|
|
|
|
|
Motor HP |
|
|
Volts |
160A |
320A |
600A |
1000A |
|
230 |
60 |
125 |
200 |
----- |
|
460 |
125 |
250 |
500 |
----- |
|
1000 |
300 |
600 |
1200 |
----- |
|
1500 |
420 |
850 |
1600 |
----- |
|
2300 |
600 |
1250 |
2400 |
----- |
|
3300 |
960 |
1920 |
3700 |
----- |
|
Transformer Load (KVA) |
|
|
Volts |
160A |
320A |
600A |
1000A |
|
230 |
66 |
133 |
250 |
415 |
|
460 |
127 |
255 |
500 |
746 |
|
1000 |
277 |
554 |
1000 |
1730 |
|
1500 |
415 |
850 |
1500 |
2600 |
|
2300 |
665 |
1330 |
2500 |
4150 |
|
3300 |
910 |
1820 |
3400 |
5700 |
|
Capacitor Load(KVAR) |
|
|
Volts |
160A |
320A |
600A |
1000A |
|
230 |
50 |
100 |
180 |
310 |
|
460 |
95 |
190 |
360 |
595 |
|
1000 |
205 |
415 |
750 |
1300 |
|
1500 |
310 |
620 |
1125 |
1450 |
|
2300 |
500 |
1000 |
1875 |
3110 |
|
3300 |
700 |
1365 |
2550 |
4275 |
|
Coil Table |
|
Voltage AC |
Suffix |
Voltage DC |
Suffix |
|
120 |
-76 |
125 |
-125 |
|
240 |
-26 |
250 |
-250 |
GREENSTONE USA
Copyright © 2001 GREENSTONE USA All rights reserved.
Revised:
June 16, 2011
|