Call us Toll Fee at: 877-206-5021    

 

 

 

 

 

Vacuum Relays

 

 

Here are some of the vacuum relays we manufacture:

 

 

 

 

Spec Model Reference Model
(Jennings)
Reference Model
(Kilovac)
Reference Model
Voltage Peak Test Max. Voltage (Peak) Operating Max. Current
Continuous
Carry Max
(RMS)
Resistance
Contact
Max.
Rated
Coil
Voltage
Mech. life
dc or 60 Hz dc or 60 Hz
          kV kV A Ω VDC  
VJ2C RJ2C --- --- 17 15 50 0.012 26.5 1X1000000
VJ4B RJ4B --- --- 17 15 50 0.012 26.5 1X1000000
VJ6B RJ6B --- --- 17 15 50 0.012 26.5 1X1000000
VJ7B RJ7B --- --- 40 25 10 0.03 26.5 1X1000000
VC-2 --- KC-2   KC-11 G2 17 15 50 0.012 26.5 1X1000000
VC-8 --- H8   KC-8    KC-12   KC-14 G8 17 15 50 0.025 26.5 1X1000000
VC-18 --- KC-18 G18 17 15 50 0.012 26.5 1X1000000
VHC-1

VHC-2

VHC-3

RJ1A-26S

RJ1H-26S

HC-1

HC-3

HC-5

--- 5 3.5 18 0.02 26.5 1X1000000
    RJ5A                
    RJ6A                
  V43A

V43B

  K43A

K43B

G43A

G43B

           
  V45A

V45B

V45C

  K45A

K45B

K45C

             
V41A

V41B

V41C

 RF42 

 RF48

K41A

K41B

K41C

G41A

G41B

G41C

6 5 30 0.02 26.5 1X1000000

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


 

TYPE

 

Type

Working voltage

Contact current

Nominal coil voltage

Contact arrangement

EVA20

400 V DC

20A

12/24 V DC

1 Form A

EVA80

400 V DC

80A

12/24 V DC

EVA120

400 V DC

120A

12/24 V DC

EVA300

400 V DC

300A

12/24 V DC

 

RATINGS

1. Coil Information

P/N#

Nominal coil voltage

Pick-up voltage (at 20°C 68°F)

Drop-out voltage (at 20°C 68°F)

Nominal operating current [±10%] (at 20°C 68°F)

Nominal operating power (at 20°C 68°F)

Max. allowable voltage

EVA20

12 V DC

Max. 9 V DC

Min. 0.5 V DC

0.33 A

3.9 W

16 V DC

EVA80

Max. 9 V DC

Min. 1 V DC

0.35 A

4.2 W

EVA120

Max. 9 V DC

Min. 1 V DC

0.35 A

4.2 W

EVA300

Max. 9 V DC

Min. 2 V DC

3.2 A

3.6 W

EVA80

24 V DC

Max. 18 V DC

Min. 2 V DC

0.176 A

4.2 W

32 V DC

EVA120

Max. 18 V DC

Min. 2 V DC

0.176 A

4.2 W

EVA300

Max. 18 V DC

Min. 4 V DC

1.85 A

3.8 W

 

 

2. Specifications

Characteristics

Name

Specifications

EVA20

EVA80

EVA120

EVA300

Contact rating

Contact Form

1 Form A

Nominal switching capacity (resistive load)

20A 400V DC

80A 400V DC

120A 400V DC (Carry current)

300A 400V DC

Short term current

40A 10min, 60A 1min (3mm2)

120A 15min, 180A 2min (15mm2)

225A 3min, 400A 30sec. (38mm2)

400A 10 min, 600A 1 min. (100mm2)

Min. switching capacity (resistive load)*1

1A 12V DC

1A 12V DC

1A 12V DC

1A 24V DC

Max. cut-off current*5

800A 300V DC (Min. 1 cycles)*2

1,200A 300V DC (Min. 1 cycle)*2

2,500A 300V DC (Min. 3 cycles)*3

Overload opening/closing rating*5

60A 400V DC (Min. 50 cycles)*2

120A 400V DC (Min. 50 cycles)*2

800A 300V DC (Min. 5 cycles)*2 120A 400V DC (Min. 50 cycles)*2

600A 400V DC (Min. 300 cycles)

Reverse direction cut-off*5

–120A 200V DC (Min. 50 cycle)*2

–120A 200V DC (Min. 50 cycle)*2

–300A 200V DC (Min. 100 cycles)

Contact voltage drop (Initial)

Max. 0.2V (By voltage drop 6 V DC 20A)

Max. 0.067 V (By voltage drop 6 V DC 20A)

Max. 0.03V (By voltage drop 6 V DC 20A)

Max. 0.06V (300 A Carry current)

Electrical characteristics

Insulation resistance (Initial)

Min. 100MΩ (at 500 V DC, Measurement at same location as Initial breakdown voltage section.)

Breakdown voltage (Initial)

Between open contacts

2,500Vrms/min. (Detection current: 10mA)

Between contact and coil

2,500Vrms/min. (Detection current: 10mA)

Operate time (at 20°C 68°F)

Max. 50ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)

Max. 30ms (Nominal coil voltage applied to the coil, excluding contact bounce time.)

Release time (at 20°C 68°F)

Max. 30ms (Nominal coil voltage applied to the coil, without diode.)

Max. 10ms (Nominal coil voltage applied to the coil, without diode.)

Mechanical characteristics

Shock resistance

Functional

For ON: Min. 196m/s2 {20 G} (Half-wave pulse of sine wave: 11ms; detection time: 10μs) For OFF: Min. 98m/s2 {10 G} (Half-wave pulse of sine wave: 11ms; detection time: 10μs)

Destructive

Min. 490 m/s2 {50 G} (Half-wave pulse of sine wave: 6ms)

Vibration resistance

Functional

10 to 200 Hz, Min.43 m/s2 {4.4 G} (Detection time: 10μs)

10 to 200 Hz, Min.44 m/s2 {4.5 G} (Detection time: 10μs)

Destructive

10 to 200 Hz, Min.43 m/s2 {4.4 G} (Time of vibration for each direction; X, Y, Z direction: 4 hours)

10 to 200 Hz, Min.44 m/s2 {4.5 G} (Time of vibration for each direction; X, Y, Z direction: 4 hours)

Expected life

Mechanical

Min. 2×105

Electrical (resistive load)

20A 400V DC Min. 3,000*2

80A 400V DC Min. 1,000*2

30A 400V DC Min. 3,000*2

300A 400V DC Min. 1,000

Conditions

Conditions for operation, transport and storage

Ambient temperature: –40 to +80°C –40 to +176°F (Storage: Max. 85°C 185°F), Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)

Ambient temperature: –40 to +85°C –40 to +185°F (Storage: Max.85°C 185°F), Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)

Unit weight (Approx.)

180 g 6.35 oz

400 g 14.11 oz

400 g 14.11 oz

750 g 26.46 oz

 

 

 

Notes:

*1. This value can change according to the switching frequency, environmental conditions, and desired reliability level, so it is recommended to check this with the actual load.

*2. The electrical load performance value for the 20A, 80A and 120 A relay applies when a varistor is connected in parallel to the coil.

*3. Condition: Nominal switching 10 cycles, each cut-off 2,500 A

*4. The coil voltage 12 V DC type and 24 V DC type have the same specifications.

*5. at L/R ≤ 1ms

 

 

 

DIMENSIONS (mm/inch)

 

 

 

 

 

 

 

 

Greenstone USA custom manufactures many different types of vacuum relays, whatever your application is we can manufacture a vacuum relay to meet your needs.

 

 

 

 

 

 

 

 

 

 

 

 

 

GREENSTONE USA
Copyright © 2001 GREENSTONE USA All rights reserved.
Revised: May 20, 2013

 

 

 

 
Google